ABOUT PT. ESTIMA REKA SAKTI

Engineering, Procurement & Construction

PT. ESTIMA REKA SAKTI
Estima Insulation is a full-service mechanical system insulation contractor specializing in industrial processing plant and oil & gas project. Estima's expertise covers a wide range of applications for the pulp and paper industry, the plastic industry, chemical industry, food processing, power generation and many other. Formed from the merger of three family owned area bussiness with more of experience between them, Estima Insulation is your source for insulation contractors. No matter how large or complex the project, Estima has the skilled union tradespeople to complete the job safely, on time and on budget. Our experience gives us the knowledge to match the insulation product and application to your need. From new construction to remodelling, we're your qualified insulation contractor for all types of insulation project.

 

Latest Project

See Detail

Articles


PRO PERL PERLITE POWDER

Perlite is not a trade name but ageneric term for naturally occurring siliceous rock. To make perlite insulation, perlite ore is crushed and segregated. Then it is heated to a point in its softening ränge where its volume expands some 4 to 25 times due to the 2 - 6 % combined water in the ore. When rapidly heated to above 870°C (1600T), the ore pops äs this water vapourizes, creating countless partial vacuum air pockets in the heat softened glassy particles which makes expanded perlite lightweight and an excellent insulator. Expanded perlite can be manufactured to weigh äs little äs 32 kg/m 3 (2 Ib/ft 3), making it t he ideal insulation for cryogenic tanks and coldboxes.

Posted by Admin Read more Comments (1) 2008-01-20 15:08:08

STEAM PIPE

The boiler shall be constructed on a heavy steel frame. The boiler pressure vessel shall be provided with adequately sized upper and lower drums. A minimum of two downcomers shall be provided and shall be located inside the furnace chamber to maximize proper thermal internal water circulation. The boiler steam drum shall be no less than 24” O.D.. The drum shall be provided with internals designed for providing steam quality in excess of 99%. Steel water tubes are to be 1½” O.D., .095 wall thickness minimum, six-pass, flexible serpentine bend design, not subject to thermal shock damage. Individual water tubes shall be easily removable and replaceable without either welding or rolling. The boiler shall have no more than two tube configurations. The boiler shall be furnished with an adequate number of tappings and inspection openings to facilitate internal boiler inspection and cleaning.

Posted by Admin Read more Comments (0) 2008-01-20 15:05:33